Home / Blog / Does Window Film Help in an Earthquake?

Does Window Film Help in an Earthquake? What FEMA and the Test Data Say

Film is sometimes described as an earthquake fix. FEMA's wording is more careful than that, and the lab data is narrower than the marketing. This post walks through what FEMA E-74 says about film, how glass actually breaks, what one industry-funded university test series found, where the sources disagree about attachment, and what California's codes and school guidance do and do not say. Where only a manufacturer or trade group says something, we say so.

Published October 6, 2026 · Armored Glass Solutions

The Mechanism

How glass actually breaks in an earthquake

Window film gets mentioned in earthquake conversations often enough that it is worth separating what it can plausibly do from what it cannot. The short version of our reading: film may help hold broken pieces together, it is not what keeps the glass from breaking, and the sources do not agree on how it should be attached.

Start with the cause. FEMA's guide to nonstructural earthquake damage, FEMA E-74, says glazing is "particularly vulnerable in flexible structures with large inter-story drifts," and that large storefront windows are also vulnerable. Drift is the sideways movement of one floor relative to the next. A window frame is bolted to the building, so when the building sways, the frame is pushed out of square. FEMA's NEHRP commentary (FEMA P-750) describes the geometry: the rectangular frame becomes a parallelogram, and the glass breaks when its edge contacts the frame. The window film industry association (IWFA) says the same thing in its education guide: the major cause of breakage in a seismic event is movement of the glass in relationship to the frame and building.

We did not find any source saying film changes how far the frame moves or how much clearance the glass has. Film is applied to the glass. The frame is a separate question, and in a building with large drift the frame is where the problem starts.

What FEMA Says

The four things glass can do, per FEMA

E-74 sorts glazing performance in earthquakes into four categories. In plain terms: the glass stays unbroken in its frame; the glass cracks but stays in its frame and keeps weather out; the glass shatters but remains in the frame in a precarious position, liable to fall at any time; or the glass falls out. E-74 adds that fallen glass can come down in shards, in small pieces, or as broken panes "held in place by film."

FEMA also says what counts as success: "Glazing that remains in place and acts as a weather barrier (even if cracked) satisfies both immediate occupancy and life-safety performance objectives." If the glass shatters or falls, E-74 says the level of hazard depends on how the glass breaks and how far it falls.

That framing is useful for judging film. The question is not whether the glass will crack. It is which category the glass lands in once it does.

Where Film Fits

Where film fits in FEMA's own advice, and where it does not

The film passage in E-74 is short and carefully hedged. It says plastic films that help hold glass fragments together are available, and that these films "may reduce seismic risk associated with dislodged fragments." It says strategic application where glazing is over an exit way, within 10 feet of one, or along interior corridors "may provide sufficient risk reduction" if the areas around the building have limited public access. It also says extending the film over the edge of the frame "is advisable not only to hold broken fragments in place but also to prevent the entire pane from falling out."

Read the verbs: may reduce, may provide. FEMA does not call film a fix, and it does not list it first. For storefront glass, E-74 puts laminated glass ahead of film: "Laminated glass will typically remain in place when broken and will prevent people or objects from falling through the opening." Film is the option for existing panes you are not replacing. For the difference between film and laminated glass in general, see our film, laminated glass and replacement comparison. And film does not turn ordinary glass into safety glass; our post on whether window film is safety glass explains the legal definition.

E-74 also lists steps that have nothing to do with film. It says "Liberal use of landscaping strips or areas with restricted pedestrian access may help to reduce the seismic risk beneath large glass panes or tall curtain walls," and "Avoid placing beds, desks, chairs or couches that are typically occupied many hours a day near large plate glass windows." Moving a desk away from a big window costs nothing and sits in the same FEMA passage as the film advice.

Two California public sources point the same direction. The state Seismic Safety Commission homeowner's guide (2005 edition) says that "large windows can be made safer by applying plastic film on them," after noting that a professional can advise on weaknesses. The Earthquake Country Alliance large windows page lists film among several fixes, after steel framing or plywood paneling and added mullions, and says to consult a qualified architect or engineer if you have large or numerous windows, especially on the ground floor. Both say "safer," not "safe."

The Test Data

What the one university test series showed

The most cited lab work on film in racking is a 2009 report from UC San Diego, SSRP 09-02, which tested storefront-type window units on a racking rig. Before the numbers, the limits, because they matter:

  • Funding. The report acknowledges financial support and technical guidance from the AIMCAL Window Film Committee, an industry group. It is a university report, but it was paid for by the window film industry.
  • What was tested. A 5-foot by 5-foot unit of 1/4-inch annealed single-pane glass in an aluminum frame, typical of mid-rise storefront construction, among 12 small-scale and 53 full-scale specimens.
  • What was not. The authors say the findings "were limited to the type of window system considered, namely, store-front type construction." Tempered, laminated and insulated glass, residential windows, mechanical anchoring and real building drift were not tested. The report itself says it "does not constitute a standard, specification, or regulation."

Within those limits, the results split in two. First, film did not stop the glass from cracking: the authors report that the cracking pattern "was not affected by the application or thickness of the film." Second, film changed what happened to the pieces. With no film, extensive cracking caused on average 74% of the glass to fall out. With 2-mil film, less than 1% fell from the specimen, and thicker film kept it under 0.75%. In plain terms, film mainly changed what happened to the pieces, not when the glass cracked.

The report is clear that this is a narrow result. It describes the research base as thin, noting that limited study had been done on film-coated windows under seismic loading, and the authors list other glass types, attachment methods and window details as future work. We read it as a useful data point for one kind of window, not a prediction for yours.

A Real Disagreement

Daylight film versus attached film: where the sources disagree

Daylight film stops a small gap short of the frame edge. Attached or anchored film is held at the frame with sealant or a mechanical system. IWFA describes daylight as the most widely used method, and says tempered glass needs a "more robust method" than daylight because it breaks into small pieces. What the sources say about earthquakes in particular does not line up neatly:

  • FEMA E-74 advises extending film over the frame edge, to hold fragments and keep the whole pane from falling out.
  • Madico, a film manufacturer, says on its natural disaster page that it does not recommend "a simple daylight installation of safety film" for earthquakes, and recommends anchoring systems. That is a manufacturer's position; the page shows no test data for it.
  • IWFA reports its own testing that included an anchored system, which it says significantly improved glass retention when anchored from the top of the window. We did not find a published report for that testing.
  • UCSD found the opposite side of the trade-off. Wet-glaze attachment, the one method it tested, lowered the drift at which the glass cracked or fell out, by about 32% and 37% on average for two damage states, because the attachment stiffens the system and concentrates stress along the glass edge. But "The attachment system, when it did not fail, held the shattered panel in place after testing."

These sources answer different questions. UCSD measured when the glass failed; E-74 and Madico are concerned with whether broken glass stays in the opening. Wet glaze was the only attachment method UCSD tested, so its result says nothing about mechanical anchors. We are not going to give you a rule here, because the sources do not give one. Whether a given opening should be daylight or attached depends on the glass, the frame and the hazard, and you should ask for the test basis for that exact setup. Attachment also comes up in a different hazard; our blast mitigation page covers why anchoring is discussed there.

California Codes

What California codes require, and what they do not say about film

The California Building Code says "Glass in glazed curtain walls, glazed storefronts and glazed partitions shall meet the seismic requirements of ASCE 7, Section 13.5.9" (Chapter 24, as reproduced on UpCodes; confirm against the official text). That section deals with the glazing system accommodating building drift, either by calculation or by testing. For public schools and community colleges, the Division of the State Architect's IR 24-2 says glazing systems must accommodate the seismic relative displacement requirements of that same section where drift is taken in the window wall. It was written for the 2016 code, so check for a newer edition.

We found no source that says film counts toward any of this. None of the FEMA, state or DSA documents we read says film satisfies the drift provisions or a seismic retrofit requirement, and we are not saying it does not; we found no source either way. That is a question for the building official or a licensed engineer. We do not assess whether a frame can handle a given drift, and we will not tell you a film install clears a code requirement.

Schools

Schools and districts: what the state guide recommends

The California guide on nonstructural earthquake hazards in schools (Cal EMA, DSA, Seismic Safety Commission and Department of Education, revised 2011) covers windows in a single entry. It says glass next to or within entrance or exit doors must be safety glass, meaning tempered or laminated, warns that fallen glass can injure people or block exits, and recommends: "Replace glass on door and glass surrounding the door with safety glazing." The word film does not appear in it.

FEMA P-1000, FEMA's school safety guide, does not discuss window film for earthquakes either. It points to the California guide and to E-74, and says a thorough evaluation is best prepared by an earthquake design professional. If you run a district, the state guide's own answer for exit-door glass is replacement with safety glazing. For how film is considered for school security, see our post on security film for schools and districts; it is a different question from earthquake performance.

The Limits

What film cannot do

3M's technical specification for a 7-mil safety film lists seismic events among the applications where it helps prevent flying glass shards, and then states the limit plainly: "THESE FILMS DO NOT PREVENT PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH." The same notice lists the factors that affect the outcome, including the film selected, type and thickness of glass, building construction and quality of window frames. Our source for that is the 3M data sheet.

Put together, here is what the sources support. Film may help hold broken fragments of an existing pane. It does not strengthen the frame, does not reduce building drift, does not stop the glass from cracking in the lab data we found, and is not shown anywhere we looked to satisfy a seismic code requirement. If glass is a hazard over an exit or a walkway, FEMA's list includes replacement glass types, restricted-access zones and furniture placement alongside film.

Installation matters too. E-74 notes that many glazing performance problems in earthquakes result from poor installation of the original glazing, such as missing clearances and improper shims. That finding is about glazing, not film. We found no source that measures film installation quality in earthquakes, but it is a fair reason to ask how an install will be done and see it in writing. Our security window film page describes what we install, and our residential page covers homes.

What to Ask For

What to ask an installer in writing

  • Glass type, thickness and size for each opening, and whether it is annealed, tempered, laminated or insulated.
  • Daylight or attached, and why. If attached, which method, and what test supports it for your frame and glass.
  • The test basis for that exact configuration. A brochure is not a test report, and a lab result on one window type is not a result for another.
  • Who assesses the frame. Drift capacity is an engineering question, and E-74, P-1000 and the state guides send it to an architect or engineer.
  • What the film is not claimed to do, in the written proposal.

Our posts on what to ask a window film installer and what a site assessment should cover go through the questions in more depth. If you want us to look at your openings, contact us and we will tell you what we think the evidence supports for each one.

Questions

Window film and earthquakes — FAQ.

Can window film stop a window from breaking in an earthquake?

No source we found says it can. Glass breaks because the building frame is pushed out of square and the glass edge hits the frame. In the UCSD lab tests, the cracking pattern was not affected by the film or its thickness. What film did in those tests was keep the pieces together: less than 1% of the glass fell from filmed specimens, against 74% on average for unfilmed ones. Those were storefront-type specimens of 1/4-inch annealed glass, and the research was funded by the AIMCAL Window Film Committee.

Does FEMA recommend window film?

FEMA E-74 says films may reduce seismic risk associated with dislodged fragments, and that strategic placement near exits and corridors may provide sufficient risk reduction if surrounding areas have limited public access. It lists laminated glass first for storefronts and also lists furniture placement and landscaping buffers. It does not present film as a fix for the glass breaking.

Does it matter whether film is attached to the frame?

The sources disagree. E-74 advises extending film over the frame edge to prevent the entire pane from falling out. Madico does not recommend a simple daylight installation for earthquakes, and IWFA reports that anchoring from the top improved retention. In the UCSD tests, wet-glaze attachment lowered the drift at which the glass cracked or fell out, although the attached panel stayed in place. Ask the installer which method is proposed and what test supports it for your frame and glass.

Is window film required or accepted for earthquake safety by California building rules?

We found no source that says so. The California Building Code requires glass in curtain walls, storefronts and partitions to meet the drift provisions of ASCE 7 Section 13.5.9, and DSA window wall guidance for public schools addresses drift in the glazing design. Neither text we read mentions film. Ask your building official or engineer before assuming film counts toward any requirement.

What does the state say schools should do about windows?

The California school guide on nonstructural earthquake hazards calls for safety glazing, meaning tempered or laminated glass, in and beside entrance and exit doors, and recommends replacing glass there that does not comply. It does not mention film. FEMA P-1000 does not mention window film for earthquakes either, and points to E-74 and an earthquake design professional for evaluation.

Sources

Where these findings came from.

  1. FEMA E-74, Reducing the Risks of Nonstructural Earthquake Damage, 4th ed. (2012), Section 6.3.1.4, Glazing, as hosted by the ATC project site. Link.
  2. FEMA P-750, 2009 NEHRP Recommended Seismic Provisions, commentary on ASCE 7 Section 13.5.9. Link.
  3. FEMA P-1000, Safer, Stronger, Smarter (2017), state-hosted copy. Link.
  4. Eva and Hutchinson, UC San Diego SSRP 09-02, Experimental evaluation of the in-plane seismic behavior of store-front window systems (2009), funded by the AIMCAL Window Film Committee; copy hosted by a film manufacturer. Link.
  5. International Window Film Association, Safety & Security Education Guide (2026). Industry source. Link.
  6. Madico, natural disaster mitigation page. Manufacturer statements. Link.
  7. 3M, Safety S70 technical specifications, Revision D (January 2025). Manufacturer statements. Link.
  8. California Building Code, Chapter 24, as reproduced on UpCodes (unofficial text; confirm with the official code). Link.
  9. DSA IR 24-2, Window Wall Systems (2016 CBC). Link.
  10. California Seismic Safety Commission, Homeowner's Guide to Earthquake Safety (2005). Link.
  11. Earthquake Country Alliance, Large Windows. Link.
  12. Cal EMA, DGS Division of the State Architect, Seismic Safety Commission and Department of Education, Guide and Checklist for Nonstructural Earthquake Hazards in California Schools (revised January 2011). Link.

Keep Reading

Is window film safety glass?

What the legal definition of safety glazing is, and where film does and does not fit.

Read the answer →

Security film vs. laminated glass vs. replacement

How to decide opening by opening, including the cases where film is the wrong recommendation.

Read the comparison →

What to ask a window film installer

The written questions to ask before any film goes on your glass.

See the questions →